- Product Detail
-
Electrolyzer water electrolysis electrodes and composite membrane s
Equipped with world-class R&D facilities, YIHO has established a systematic and independent R&D system covering materials to equipment.
Our electrolyzer cells and core materials have undergone over 400,000 hours of testing, resulting in two generations of high-efficiency electrode technology and the development of high-performance composite membranes.
Our products have superior parameters and are highly reliable. We have already established large-scale production capabilities for our core materials.





High-efficiency water electrolysis hydrogen production electrolyzer
YIHO offers a series of alkaline electrolyzers with capacities ranging from 0.5 to 2000 Nm³/h. To cater to various hydrogen production scenarios, we provide two product series: E and C.
Product series
Series E
Series C
Application Scenarios
grid electricity/off-peak electricity hydrogen production
off-grid hydrogen production from wind/solar power
Product Features
Economical
low DC power consumption
rapid cold start
Safe
long-term stable operation
high current density
Efficient
rapid cold start
wide response range
Low-energy Hydrogen Production Series (suitable for stable power sources)
Capacity
(Nm3/h)
Model
Weight
(T)
DC power Consumption
(kWh/Nm3)
Cold start Period
(Min.)
Load Range
(%)
Working Pressure
(Mpa)
Working
Temperature
(℃)
2
CY1-2E
0.55
≤4.0
≤1
25-150
1.6/3.2
95±5
5
CY1-5E
1.2
10
CY1-10E
1.5
20
CY1-20E
3.2
30
CY1-30E
3.6
50
CY1-50E
4.3
80
CY1-80E
7.2
1.6
100
CY1-100E
8
200
CY1-200E
12
≤4.0
≤15
25-150
1.6
95±5
300
CY1-300E
22
400
CY1-400E
26
500
CY1-500E
30
800
CY1-800E
35
1000
CY1-1000E
38
1200
CY1-1200E
42
High-current Density Hydrogen Production Series(suitable for fluctuating renewable energy sources)
Capacity
(Nm3/h)
Model
Weight
(T)
DC power Consumption
(kWh/Nm3)
Cold start Period
(Min.)
Load Range
(%)
Working Pressure
(Mpa)
Working
Temperature
(℃)
2
CY1-2C
0.45
≤4.3
≤1
15-150
1.6/3.2
95±5
5
CY1-5C
0.6
10
CY1-10C
1.2
20
CY1-20C
1.5
30
CY1-30C
1.8
50
CY1-50C
3.4
80
CY1-80C
3.9
1.6
100
CY1-100C
4.3
200
CY1-200C
8
≤4.3
≤15
15-150
1.6
95±5
300
CY1-300C
10
400
CY1-400C
18
500
CY1-500C
20
800
CY1-800C
26
1000
CY1-1000C
28
1200
CY1-1200C
31
Integrated solution for electrolytic water hydrogen production system
Based on our standard product offerings, we provide customized hydrogen system solutions tailored to different hydrogen production scenarios and customer needs
• Our solutions improve renewable energy utilization,
• Reduce overall hydrogen production costs,
• Optimize space utilization,
• Offer the best return on investment,
• Collaborate with upstream and downstream industry partners to provide integrated solutions.
Applications fields:• Off-grid renewable hydrogen production

• Hydrogen-based marine fuel production


• Chemical coupling of green hydrogen

• Integrated hydrogen production and refueling station


• Offshore wind-powered hydrogen production

• Green hydrogen in metallurgy


Customized post-processing system for a 1000Nm3/h electrolyzer.
Module
Parameters
1 VS 1
4 VS 1
H2 Gas-Liquid Separation Device
H2 Processing Capacity (Nm3/h)
1100(1200)
4400(4800)
Working Pressure
(Mpa)
1.6
H2 Purification Device
H2 Processing Capacity (Nm3/h)
1100(1200)
4400(4800)
≥99.999
Dew point℃
≤-50
Output Pressure
1.6
Regeneration method: three-tower process, product hydrogen regeneration, zero emissions
Water electrolysis hydrogen production test system
We have established a 12MW multi-functional electrolyzer test base, one of the most powerful electrolyzer testing facilities in China. The test base is now fully operational, capable of testing systems with a maximum current of DC 12,000A and 840V. It is equipped with a 2500Nm³/h hydrogen production system and a power system testing capability. The testing conditions of the base have been highly recognized by third-party authoritative testing institutions.
Product development requires feedback from operational data. Testing new products is essential. The test base will provide strong support for the development of our own products and technological iterations.
We are building a hydrogen testing service platform to provide important support for industry standard development and offer product testing services to more hydrogen energy companies.
Comprehensive DC power supply solutions for hydrogen electrolyzers.
Applications fields:
• Grid-tied: Grid power, hybrid (grid + renewables)
• Off-grid: AC grid, DC grid
• DC power supply products: SCR rectifier, IGBT rectifier


DC supply voltage
DC 1050V
Technical solution
Three-phase PWM chopper with filter
Output voltage
Adjustable from 0 - 0.98Udc
Output current
750A for Type 1 module, 3600A for Type 2 module
Module paralleling
Up to 32 modules can be paralleled
Cooling:
Water/wind cooling
Multi-module interleaving
Supported
Specifications
DC 12000
Rated voltage
Adaptable 200V-600VAC 3PH 50/60Hz (corresponding to 0-1.35Uac VDC output)
Rated current
12000A DC
Dimensions
2200*1000*2000(WxDxH)
Operation Mode
12 /24-pulse rectification
Cooling
Water cooling
Voltage and current Control
Dual-loop control with input signal ramp function and hardware safety interlock
Control corresponding period
Less than 0.5ms, output signal delay 1/6 power cycle
Communication mode
Modbus-RTU/Modbus-TCP, others optional
HMI
Graphical HMI with real-time display of voltage, current, power, and control parameter settings
Gas-Liquid Separation Device & Purification Device


100-1500Nm3/h Gas-Liquid Separation Parameters
1
H2 output
100-1500Nm³/h(Rated)
2
O2 output
50-750Nm³/h(Rated)
3
H2 purity
≥99%
4
O2 purity
≥98.5%
7
Pressure
0.8-1.6Mpa(G), adjustable
8
Temperature
≤100℃
100-1500Nm3/h Gas-Liquid Separation Device Specifications
Serial No.
H2 output
Dimensions (m)
Weight (T)
1
100 Nm³/h
4*2*2.8
4.2
2
200 Nm³/h
4.7*2.4*2.8
4.7
3
1000 Nm³/h
5.5*3.5*6
22.5
4
1500 Nm³/h
6*3.5*6
25.5
100-4000Nm3/h Purification Device Parameters
1
H2 purity
≥99.999%
2
H2 output
100-4000Nm3/h
3
Dew point
≤-55℃
4
Dust
<1.0um
5
Temperature
≤40℃
6
Pressure
1.55Mpa
100-4000Nm3/h Purification Device Sepecifications
Serial No.
H2 output
Dimensions (m)
Weight (T)
1
100 Nm³/h
1.4*1.2*3
2.2
2
200 Nm³/h
3*2.4*2.8
3.2
3
1000 Nm³/h
4.8*2.2*3.5
11
4
1500 Nm³/h
5*2.5*4
15
5
4000Nm³/h
7.6*6*7.8
33
6
6000Nm³/h
7.6*6*7.8
46
Electrolytic Hydrogen Production
Electrolyzer water electrolysis electrodes and composite membrane s
Categories:
keyword:
Electrolytic Hydrogen Production
Factory
FAQ
Related Projects
Related Product