Electrolytic Hydrogen Production
Electrolytic Hydrogen Production
Green-hydrogen-in-metallurgy(1735610628853).jpg
  • Product Detail
  • Electrolyzer water electrolysis electrodes and composite membrane s
    Equipped with world-class R&D facilities, YIHO has established a systematic and independent R&D system covering materials to equipment.
    Our electrolyzer cells and core materials have undergone over 400,000 hours of testing, resulting in two generations of high-efficiency electrode technology and the development of high-performance composite membranes. 
    Our products have superior parameters and are highly reliable. We have already established large-scale production capabilities for our core materials.

     

     

    High-efficiency water electrolysis hydrogen production electrolyzer
    YIHO offers a series of alkaline electrolyzers with capacities ranging from 0.5 to 2000 Nm³/h. To cater to various hydrogen production scenarios, we provide two product series: E and C.

     

    Product series

    Series E

    Series C

    Application Scenarios

    grid electricity/off-peak electricity hydrogen production

    off-grid hydrogen production from wind/solar power

    Product Features

    Economical

    low DC power consumption

    rapid cold start

    Safe

    long-term stable operation

    high current density

    Efficient

    rapid cold start

    wide response range

     

    Low-energy Hydrogen Production Series (suitable for stable power sources)

    Capacity

    (Nm3/h)

    Model

    Weight

    (T)

    DC power Consumption

    (kWh/Nm3)

    Cold start Period

    (Min.)

    Load Range

    (%)

    Working Pressure

    (Mpa)

    Working

    Temperature

    (℃)

    2

    CY1-2E

    0.55

    ≤4.0

    ≤1

    25-150

    1.6/3.2

    95±5

    5

    CY1-5E

    1.2

    10

    CY1-10E

    1.5

    20

    CY1-20E

    3.2

    30

    CY1-30E

    3.6

    50

    CY1-50E

    4.3

    80

    CY1-80E

    7.2

    1.6

    100

    CY1-100E

    8

    200

    CY1-200E

    12

    ≤4.0

    ≤15

    25-150

    1.6

    95±5

    300

    CY1-300E

    22

    400

    CY1-400E

    26

    500

    CY1-500E

    30

    800

    CY1-800E

    35

    1000

    CY1-1000E

    38

    1200

    CY1-1200E

    42

    High-current Density Hydrogen Production Series(suitable for fluctuating renewable energy sources)

    Capacity

    (Nm3/h)

    Model

    Weight

    (T)

    DC power Consumption

    (kWh/Nm3)

    Cold start Period

    (Min.)

    Load Range

    (%)

    Working Pressure

    (Mpa)

    Working

    Temperature

    (℃)

    2

    CY1-2C

    0.45

    ≤4.3

    ≤1

    15-150

    1.6/3.2

    95±5

    5

    CY1-5C

    0.6

    10

    CY1-10C

    1.2

    20

    CY1-20C

    1.5

    30

    CY1-30C

    1.8

    50

    CY1-50C

    3.4

    80

    CY1-80C

    3.9

    1.6

    100

    CY1-100C

    4.3

    200

    CY1-200C

    8

    ≤4.3

    ≤15

    15-150

    1.6

    95±5

    300

    CY1-300C

    10

    400

    CY1-400C

    18

    500

    CY1-500C

    20

    800

    CY1-800C

    26

    1000

    CY1-1000C

    28

    1200

    CY1-1200C

    31

     

    Integrated solution for electrolytic water hydrogen production system
    Based on our standard product offerings, we provide customized hydrogen system solutions tailored to different hydrogen production scenarios and customer needs
    • Our solutions improve renewable energy utilization, 
    • Reduce overall hydrogen production costs, 
    • Optimize space utilization, 
    • Offer the best return on investment,
    • Collaborate with upstream and downstream industry partners to provide integrated solutions.


    Applications fields:

    Off-grid renewable hydrogen production

     

    • Hydrogen-based marine fuel production 

     

    • Chemical coupling of green hydrogen

    • Integrated hydrogen production and refueling station

     


    • Offshore wind-powered hydrogen production

     

    • Green hydrogen in metallurgy 

     

    Customized post-processing system for a 1000Nm3/h electrolyzer.

     

    Module

    Parameters

    1 VS 1

    4 VS 1

    H2 Gas-Liquid Separation Device

    H2 Processing Capacity (Nm3/h)

    1100(1200)

    4400(4800)

    Working Pressure

    (Mpa)

    1.6

    H2 Purification Device

     

    H2 Processing Capacity (Nm3/h)

    1100(1200)

    4400(4800)

     

    ≥99.999

    Dew point℃

    ≤-50

    Output Pressure

    1.6

    Regeneration method: three-tower process, product hydrogen regeneration, zero emissions

     

    Water electrolysis hydrogen production test system 
    We have established a 12MW multi-functional electrolyzer test base, one of the most powerful electrolyzer testing facilities in China. The test base is now fully operational, capable of testing systems with a maximum current of DC 12,000A and 840V. It is equipped with a 2500Nm³/h hydrogen production system and a power system testing capability. The testing conditions of the base have been highly recognized by third-party authoritative testing institutions. 
    Product development requires feedback from operational data. Testing new products is essential. The test base will provide strong support for the development of our own products and technological iterations. 
    We are building a hydrogen testing service platform to provide important support for industry standard development and offer product testing services to more hydrogen energy companies.


    Comprehensive DC power supply solutions for hydrogen electrolyzers.
    Applications fields:
    • Grid-tied: Grid power, hybrid (grid + renewables)
    • Off-grid: AC grid, DC grid
    • DC power supply products: SCR rectifier, IGBT rectifier

     

     

    DC supply voltage

    DC 1050V

    Technical solution

    Three-phase PWM chopper with filter

    Output voltage

    Adjustable from 0 - 0.98Udc

    Output current

    750A for Type 1 module, 3600A for Type 2 module

    Module paralleling

    Up to 32 modules can be paralleled

    Cooling:

    Water/wind cooling

    Multi-module interleaving

    Supported

     

    Specifications

    DC 12000

    Rated voltage

    Adaptable 200V-600VAC 3PH 50/60Hz (corresponding to 0-1.35Uac VDC output)

    Rated current

    12000A DC

    Dimensions

    2200*1000*2000(WxDxH)

    Operation Mode

    12 /24-pulse rectification

    Cooling

    Water cooling

    Voltage and current Control

    Dual-loop control with input signal ramp function and hardware safety interlock

    Control corresponding period

    Less than 0.5ms, output signal delay 1/6 power cycle

    Communication mode

    Modbus-RTU/Modbus-TCP, others optional

    HMI

    Graphical HMI with real-time display of voltage, current, power, and control parameter settings

     

     Gas-Liquid Separation Device & Purification Device

     

    100-1500Nm3/h Gas-Liquid Separation Parameters

    1

    H2 output

    100-1500Nm³/h(Rated)

    2

    O2 output

    50-750Nm³/h(Rated)

    3

    H2 purity

    ≥99%

    4

    O2 purity

    ≥98.5%

    7

    Pressure

    0.8-1.6Mpa(G), adjustable

    8

    Temperature

    ≤100℃

     

    100-1500Nm3/h Gas-Liquid Separation Device Specifications

    Serial No.

    H2 output

    Dimensions (m)

    Weight (T)

    1

    100 Nm³/h

    4*2*2.8

    4.2

    2

    200 Nm³/h

    4.7*2.4*2.8

    4.7

    3

    1000 Nm³/h

    5.5*3.5*6

    22.5

    4

    1500 Nm³/h

    6*3.5*6

    25.5

     

    100-4000Nm3/h Purification Device Parameters

    1

    H2 purity

    ≥99.999%

    2

    H2 output

    100-4000Nm3/h

    3

    Dew point

    ≤-55℃

    4

    Dust

    <1.0um

    5

    Temperature

    ≤40℃

    6

    Pressure

    1.55Mpa

     

    100-4000Nm3/h Purification Device Sepecifications

    Serial No.

    H2 output

    Dimensions (m)

    Weight (T)

    1

    100 Nm³/h

    1.4*1.2*3

    2.2

    2

    200 Nm³/h

    3*2.4*2.8

    3.2

    3

    1000 Nm³/h

    4.8*2.2*3.5

    11

    4

    1500 Nm³/h

    5*2.5*4

    15

    5

    4000Nm³/h

    7.6*6*7.8

    33

    6

    6000Nm³/h

    7.6*6*7.8

    46

Electrolytic Hydrogen Production

Electrolyzer water electrolysis electrodes and composite membrane s

keyword:

Electrolytic Hydrogen Production

Factory

FAQ

Related Projects

Product Inquiry

We will contact you within one business day. Please pay attention to your mail.

%{tishi_zhanwei}%